The presentation covers the physical principles behind the operation of the eddy current transducer system, outlines the steps for successful implementation of measurements on industrial machines and provides an overview of sample project results.
The presentation covers the physical principles behind the operation of the eddy current transducer system, outlines the steps for successful implementation of measurements on industrial machines and provides an overview of sample project results.
Broken or fractured rotor bars are found as elevated Pole Pass Frequency (PPF) sidebands of line fre- quency (LF). PPF is calculated using the synchronous speed minus the running speed times the number of poles..
In this interview, Don will share how to identify and confirm motor anomalies with electric motor testing. Listen to Don as he shares is background knowledge in Motor Testing…
The primary difference between an induction motor and a wound rotor motor is that the rotor has windings, slip rings and a variable resistance in order to vary speed or soft start an application...
One of the most frequently quoted studies related to electric motor reliability is a 1983 Electric Power Research Institute (EPRI) project performed by General Electric...